ALL1000-3300W
INSTALLATION INSTRUCTIONS
Aladdin Light Lift, Inc. (256) 429-9700
61 Shields Road (877) 287-4601
Huntsville, AL 35811 www.aladdinlightlift.com
Patent #5105349
WARNING: Disconnect power source before servicing to avoid electrical shock
CAUTION: To Reduce the Risk of Electric Shock or Injury, Use Indoors Only.
Light and motor circuits are rated at AC 110V
Not suitable for air handling spaces
Pour usage seulement dans un endroit
Avec acces au dessus du plafonds
Model Number:ALL1000(1000lb. rated working load,7/32” steel galvanized lay cable,1.67amp,50/60Hz)
__ x Greeneld _(if checked)
Light lift is equipped with a 35’ cable unless checked below:
______65’
______90’
______120’
Light lift is equipped with two 1,650 watt (15 amp)
lighting circuits. Total capacity 3300 watts.
________________________
Manufacture Date © 2013 All Rights Reserved
Vedere la pagina 0
1 2 3 4 5 6 ... 12 13

Sommario

Pagina 1 - ALL1000-3300W

ALL1000-3300W INSTALLATION INSTRUCTIONSAladdin Light Lift, Inc. (256) 429-970061 Shields Road (877) 287-4601Huntsville, AL 35811 www

Pagina 2 - ALL1000 Parts Bag List

STEP 23Adjust screw collar rings so top of canopy is just below edge of bottom contact plate. Canopy should be at least 1 ¾” deep. See Diagram I.Neve

Pagina 3

STEP 27Tighten xture coupler set screws using supplied 3/32” Allen wrench. Fixture coupler set screws have thread lock already applied at factory. S

Pagina 4

ALL1000 TROUBLESHOOTING GUIDETECH SUPPORT: (877) 287-4601 Monday through Friday 8:00am to 4:00pm CSTI. Troubleshooting and installation must be perfo

Pagina 5 - Sheetrock

ALL1000 TROUBLESHOOTING GUIDE cont. 1. Conrm ALL1000 is at the CEILING POSITION. If not, use the controller to operate the ALL1000 to the CEILING P

Pagina 6

Read the following guidelines prior to installing the ALL1000:I. e ALL1000 must be installed by a licensed, bonded and insured electrician. II. e A

Pagina 7

STEP 1Determine where ALL1000 will mount on ceiling joists. ALL1000 must be installed level, in an accessible location directly above chandelier.Neve

Pagina 8

STEP 5Attach the 1/2” conduit connector on ceiling box to bottom of conduit assembly. Once completely inserted, tighten set screw on conduit connecto

Pagina 9

STEP 7Position ALL1000 where ceiling box will be centered in ceiling hole. Weight and bottom contact plate assembly should hang down through ceiling

Pagina 10

STEP 9Shim and adjust ALL1000 so that winch cable hangs plumb through center of hole in top contact plate on ceiling box. See Diagram E. Look up at

Pagina 11

STEP 11Turn o supply power before wiring ALL1000. Turn o motor switch in square box. Wire motor switch with 110V wiring. e 110V motor feed must b

Pagina 12 - ALL1000 TROUBLESHOOTING GUIDE

STEP 13Remove dust cover and remove paper tape from winch drum while keeping tension on winch cable.Never operate the ALL1000 without tension on the c

Pagina 13 - Warranty Agreement